Can a System Handle Brown/Blackouts on only the GPU?
I am planning to build a multipurpose home server. It will be a NAS, virtualization host, and have the typical selfhosted services. I want all of these services to have high uptime and be protected from power surges/balckouts, so I will put my server on a UPS.
I also want to run an LLM server on this machine, so I plan to add one or more GPUs and pass them through to a VM. I do not care about high uptime on the LLM server. However, this of course means that I will need a more powerful UPS, which I do not have the space for.
My plan is to get a second power supply to power only the GPUs. I do not want to put this PSU on the UPS. I will turn on the second PSU via an Add2PSU.
In the event of a blackout, this means that the base system will get full power and the GPUs will get power via the PCIe slot, but they will lose the power from the dedicated power plug.
Obviously this will slow down or kill the LLM server, but will this have an effect on the rest of the system?
What's wrong with 2 PSUs if both of them are connected to the same ground? I thought multiple PSUs is common in the server space too.
Server PSUs are designed to be identical and work on parallel (though depending on platform, they can be configured as primary/hot spare, too). I'd be concerned about potential difference in power, especially with two non-matching PSUs. It would probably be fine, but not probably enough for me to trust my stuff to it. They're just not designed or tested to operate like that, so they may behave unexpectedly.